Hitachi shops faced annoyance times two:
1. xpinfo does not work on non-Hitachi storage for example Pure storage
2. xpinfo does not work on hpvm guests depending on how the storage is passed through from the hpvm host
I now present xpinfonew which though raw and unfnished
The output:
myserv0:root > ./xpinfonew
Device path ldev
==========================================================================
/dev/rdisk/disk111 =:=
/dev/rdisk/disk12 30:86
/dev/rdisk/disk172 03:f3
/dev/rdisk/disk215 46:2c
/dev/rdisk/disk216 46:30
/dev/rdisk/disk217 46:34
/dev/rdisk/disk218 46:38
/dev/rdisk/disk219 46:28
/dev/rdisk/disk220 46:25
/dev/rdisk/disk221 46:27
/dev/rdisk/disk222 46:2a
/dev/rdisk/disk223 46:2e
/dev/rdisk/disk224 46:32
/dev/rdisk/disk225 46:2b
/dev/rdisk/disk226 46:2f
/dev/rdisk/disk227 46:33
/dev/rdisk/disk237 46:37
/dev/rdisk/disk238 46:36
/dev/rdisk/disk239 46:26
/dev/rdisk/disk240 46:29
/dev/rdisk/disk241 46:2d
/dev/rdisk/disk242 46:31
/dev/rdisk/disk243 46:35
/dev/rdisk/disk244 46:39
/dev/rdisk/disk4 aa:bf
/dev/rdisk/disk5 8b:c3
/dev/rdisk/disk6 03:a6
/dev/rdisk/disk9 01:00
myserv0:root > ./xpinfonew raw
Device path ldev
==========================================================================
/dev/rdisk/disk111 =
/dev/rdisk/disk12 3086
/dev/rdisk/disk172 03f3
/dev/rdisk/disk215 462c
/dev/rdisk/disk216 4630
/dev/rdisk/disk217 4634
/dev/rdisk/disk218 4638
/dev/rdisk/disk219 4628
/dev/rdisk/disk220 4625
/dev/rdisk/disk221 4627
/dev/rdisk/disk222 462a
/dev/rdisk/disk223 462e
/dev/rdisk/disk224 4632
/dev/rdisk/disk225 462b
/dev/rdisk/disk226 462f
/dev/rdisk/disk227 4633
/dev/rdisk/disk237 4637
/dev/rdisk/disk238 4636
/dev/rdisk/disk239 4626
/dev/rdisk/disk240 4629
/dev/rdisk/disk241 462d
/dev/rdisk/disk242 4631
/dev/rdisk/disk243 4635
/dev/rdisk/disk244 4639
/dev/rdisk/disk4 aabf
/dev/rdisk/disk5 8bc3
/dev/rdisk/disk6 03a6
/dev/rdisk/disk9 0100
cat xpinfonew
#!/bin/ksh
# Get ldev from any disk regardless of storage provider
#
# 10/26/2017 Steven “Shmuel” Protter steven.protter@hcl.com
#
echo “Device path \t\t ldev ”
echo “==========================================================================”
ioscan -NfnCdisk | awk ‘/rdisk/{ print $(NF) }’ | awk -F_ ‘{ print $1 }’ | sort -u |while read -r dv
do
ldev=$(/var/adm/bin/getldev.ksh ${dv} ${1} );
echo “${dv} \t ${ldev}”
done
The code:
cat /var/adm/bin/getldev.ksh
#!/bin/ksh
# Get ldev from any disk regardless of storage provider
#
# 10/26/2017 Steven “Shmuel” Protter steven.protter@hcl.com
#
argies=$#
if [ $argies -eq 0 ]
then
echo “———— 1 argument required device path ex: /dev/rdisk/disk101 ————-”
exit 1
fi
dv=$1
fmt=$2
## /usr/sbin/scsimgr lun_map -D ${dv} | awk ‘/World Wide Identifier/{ print $(NF) }’
rldev=$(/usr/sbin/scsimgr lun_map -D ${dv} | awk ‘/World Wide Identifier/{ print substr ( $NF, length($NF) – 3, length($NF) ) }’);
l1=$(echo ${rldev} | awk ‘{ print substr ( $NF, length($NF) – 3, 2 ) }’);
l2=$(echo ${rldev} | awk ‘{ print substr ( $NF, length($NF) – 1, length($NF) ) }’);
### echo “raw: ${rldev} l1: ${l1} l2: ${l2} …”
if [ “$fmt” = “raw” ]
then
echo ${rldev}
else
echo “${l1}:${l2}”
fi
Should work on any SAN based storage
Tags: HP-UX, hpux, storage ldev, storage ldev works in hpvm guests, xpinfo improvement